Reagent Kit for Prothrombin Time Determination (Techplastin Test) under TU 21.20.23-079-42349142-2020

Reagent Kit for Prothrombin Time Determination (Techplastin Test) under TU 21.20.23-079-42349142-2020

The reagent kit is designed for determining prothrombin time using the Techplastin Test. The kit contains lyophilized rabbit brain thromboplastin-calcium mixture with buffer, preservatives, and stabilizers. It is available in several configurations to meet different laboratory needs.

Configuration No. 1 (Cat. No. 608)

  • Techplastin (lyophilized thromboplastin-calcium mixture from rabbit brain, buffer, preservatives, and stabilizers), 2 ml – 4 vials
  • Instructions for use
  • Certificate (Passport)

Configuration No. 2 (Cat. No. 607)

  • Techplastin (lyophilized thromboplastin-calcium mixture from rabbit brain, buffer, preservatives, and stabilizers), 5 ml – 4 vials
  • Instructions for use
  • Certificate (Passport)

Configuration No. 3 (Cat. No. 140)

  • Techplastin (lyophilized thromboplastin-calcium mixture from rabbit brain, buffer, preservatives, and stabilizers), 2 ml – 4 vials
  • Calibrator plasma (lyophilized), 1 ml – 1 vial
  • Instructions for use
  • Certificate (Passport)

Configuration No. 4 (Cat. No. 131)

  • Techplastin (lyophilized thromboplastin-calcium mixture from rabbit brain, buffer, preservatives, and stabilizers), 5 ml – 4 vials
  • Calibrator plasma (lyophilized), 1 ml – 1 vial
  • Instructions for use
  • Certificate (Passport)

Configuration No. 5 (Cat. No. 748)

  • Techplastin (thromboplastin-calcium suspension from rabbit brain, buffer, preservatives, and stabilizers), 10 ml suspension – 4 vials
  • Instructions for use
  • Certificate (Passport)

Configuration No. 6 (Cat. No. 735)

  • Techplastin (thromboplastin-calcium suspension from rabbit brain, buffer, preservatives, and stabilizers), 10 ml suspension – 10 vials
  • Instructions for use
  • Certificate (Passport)

If your organization wants to sell medical equipment, medical products or medical consumables in Russia, for example, Reagent Kit for Prothrombin Time Determination (Techplastin Test) under TU 21.20.23-079-42349142-2020, then our information portal MEDCOMMERCE can help you with this. To do this, simply fill out the feedback form by clicking on the link FEEDBACK FORM.